Options and spareparts for BFI inverters
For our BFI inverters we offer a variety of different options and accessories such as communication modules, boards, brake resistors, main switches, cables, etc.
Internal options to be placed inside the drives |
|||||
---|---|---|---|---|---|
Communication board to be placed inside BFI |
|||||
Name |
Function |
Item number |
BFI-E3 |
BFI-H3 |
BFI-P2 |
ABCC-ECT |
EtherCat 2-port Module |
63163 |
No |
Yes |
Yes |
ABCC-EIT_2P |
Modbus TCP 2 port Module |
63165 |
No |
Yes |
Yes |
ABCC-PRT_2P |
ProfiNet 2 port Module |
63164 |
No |
Yes |
Yes |
ABCC-EIPT_2P |
Ethernet IP 2 port Module |
63122 |
No |
Yes |
Yes |
ABCC-DPV1-2 |
Profibus DP D-sub Module |
63142 |
No |
Yes |
Yes |
ABCC-DEV-2 |
Devicenet Module |
63120 |
No |
Yes |
Yes |
ABCC-CCL |
CC-Link Module |
63250 |
No |
Yes |
Yes |
Option board to be placed inside BFI | |||||
Name |
Function |
Item number |
BFI-E3 |
BFI-H3 |
BFI-P2 |
ODP-2ROUT-BFI |
Second relay output card. Converts transistor output to relay output |
63112 |
Yes |
No |
No |
OPT-2-EXTIO-BFI |
Extended I/O, 3 digital inputs, 1 relay output |
63123 |
No |
Yes |
Yes |
OPT-2-CASCD-BFI |
Extended Relay, 3 relay outputs |
63119 |
No |
Yes |
Yes |
OPT-2-ENCOD-BFI |
TTL Encoder Module, 5 VDC |
63121 |
No |
No |
Yes |
OPT-2-ENCHT-BFI |
HTL Encoder Module, 12-30 VDC |
63170 |
No |
No |
Yes |
Brake resistor board to be put inside BFI | |||||
Name |
Function |
Item number |
BFI-E3 |
BFI-H3 |
BFI-P2 |
OD-BR100-BFI |
Internal brake resistor for IP20, 100ohm, 200W |
63101 |
Yes |
No |
Yes |
OD-BRES4-BFI |
Internal brake resistor, IP55, 33 ohm, 500W, Size4 and Size5 |
63230 |
No |
No |
Yes |
External options |
|||||
---|---|---|---|---|---|
Main switch | |||||
Name |
Function |
Item number |
BFI-E3 |
BFI-H3 |
BFI-P2 |
OPT-2-ISOL4-BFI |
Isolator Switch Box, Size 4. Directly bolt on to the drive. |
63150 |
No |
Yes |
Yes |
OPT-2-ISOL5-BFI |
Isolator Switch Box, Size 5. Directly bolt on to the drive. |
63151 |
No |
Yes |
Yes |
Communication | |||||
Name |
Function |
Item number |
BFI-E3 |
BFI-H3 |
BFI-P2 |
OPT-2-ETHEG-BFI |
External Ethernet Gateway with Modbus TCP for BFI. |
63251 |
Yes |
Yes |
Yes |
OPT-3-STICK-BFI |
BFI SmartStick Bluetooth, Copy/Paste Parameters/PLC-program, Supports Smartphones and BFI-Tools on Windows 10. |
63489 |
Yes |
Yes |
Yes |
OPT-3-PCKIT-BFI |
BFI SmartStick Bluetooth, Copy/Paste Parameters/PLC-program, Supports Smartphones and BFI-Tools on Windows 7, 8, 10, NFC. |
63491 |
Yes |
Yes |
Yes |
OPT-2-J45SP |
RS485 Serial communication Data Cable 2-port Splitter for Modbus RTU and CANopen. |
63148 |
Yes |
Yes |
Yes |
OPT-2-RJTRM-BFI |
End termination resistor RJ45 plug for CANopen and Modbus RTU communication. |
63202 |
Yes |
Yes |
Yes |
Parameter unit | |||||
Name |
Function |
Item number |
BFI-E3 |
BFI-H3 |
BFI-P2 |
OPT-2-OPPAD-BFI |
TFT Remote External Keypad. |
63201 |
Yes |
Yes |
Yes |
OPT-2-OPORT-BFI |
Basic External Keypad, 5 digits. |
63141 |
Yes |
Yes |
Yes |
Cables | |||||
Name |
Function |
Item number |
BFI-E3 |
BFI-H3 |
BFI-P2 |
OPT-J4505-BFI |
RS-485 Data Cable 0,5m. |
63144 |
Yes |
Yes |
Yes |
OPT-J4510-BFI |
RS-485 Data Cable 1,0m. |
63145 |
Yes |
Yes |
Yes |
OPT-J4530-BFI |
RS-485 Data Cable 3,0m. |
63146 |
Yes |
Yes |
Yes |
CAB 113 |
3m cable with 9-pole D-sub and RJ-45 between X2 HMI and BFI for Modbus RTU |
660000290 |
Yes |
Yes |
Yes |
CAB 114 |
3m cable for screwterminals and RJ-45 between PLC and BFI for Modbus RTU |
660000291 |
Yes |
Yes |
Yes |
CAB 115 |
3m cable with USB and RJ45 (RS485) between PC and BFI for BFI-Tools |
660000292 |
Yes |
Yes |
Yes |
CAB 154 |
3m cable with 9-pole D-sub and RJ-45 between X2 control and BFI-P2/E3 for CANopen |
1000-1179 |
Yes |
No |
Yes |
CAB 155 |
3m cable for screwterminals and RJ-45 between PLC and BFI-P2/E3 for CANopen |
1000-1180 |
Yes |
No |
Yes |
Software | |||||
Name |
Function |
Item number |
BFI-E3 |
BFI-H3 |
BFI-P2 |
BFI-Tools PLC-licence |
BFI-Tools PLC-licence |
63300 |
No |
Yes |
Yes |
Sinusidol filter for sinusidol voltage to motor (link to technical documentation) |
|||||
Name |
Function |
Item number |
BFI-E3 |
BFI-H3 |
BFI-P2 |
TNR 29848 |
Sine Wave Filter Un=400 VAC, In=4,5A, fn<=70Hz, fs=4 to16kHz |
318017 |
Yes |
Yes |
Yes |
TNR 29849 |
Sine Wave Filter Un=400 VAC, In=6,5A, fn<=70Hz, fs=4 to16kHz |
318018 |
Yes |
Yes |
Yes |
TNR 29850 |
Sine Wave Filter Un=400 VAC, In=8A, fn<=70Hz, fs=4 to16kHz |
318019 |
Yes |
Yes |
Yes |
TNR 29851 |
Sine Wave Filter Un=400 VAC, In=10A, fn<=70Hz, fs=4 to16kHz |
318026 |
Yes |
Yes |
Yes |
TNR 29739 |
Sine Wave Filter Un=400 VAC, In=18A, fn<=70Hz, fs=4 to16kHz |
318027 |
Yes |
Yes |
Yes |
TNR 29740 |
Sine Wave Filter Un=400 VAC, In=24A, fn<=70Hz, fs=4 to16kHz |
318028 |
Yes |
Yes |
Yes |
TNR 29741 |
Sine Wave Filter Un=400 VAC, In=32A, fn<=70Hz, fs=4 to16kHz |
318029 |
Yes |
No |
Yes |
TNR 29854 |
Sine Wave Filter Un=400 VAC, In=42A, fn<=70Hz, fs=4 to16kHz |
318025 |
Yes |
No |
Yes |
TNR 29855 |
Sine Wave Filter Un=400 VAC, In=48A, fn<=70Hz, fs=4 to16kHz |
TBD |
Yes |
Yes |
Yes |
TNR 29806 |
Sine Wave Filter Un=400 VAC, In=66A, fn<=70Hz, fs=4 to16kHz |
TBD |
Yes |
Yes |
Yes |
TNR 29856 |
Sine Wave Filter Un=400 VAC, In=75A, fn<=70Hz, fs=4 to16kHz |
TBD |
Yes |
No |
Yes |
TNR 29765 |
Sine Wave Filter Un=400 VAC, In=90A, fn<=70Hz, fs=4 to16kHz |
TBD |
Yes |
No |
Yes |
Input chokes to reduce harmonic currents and protection against voltage spikes | |||||
Name |
Function |
Item number |
BFI-E3 |
BFI-H3 |
BFI-P2 |
1x200-240 VAC |
|
|
|
|
|
OPT-2-L1016-20-BFI |
Input AC-choke IP20 1-ph 230V, 16A |
63124 |
Yes |
Yes |
Yes |
OPT-2-L1016-66-BFI |
Input AC-choke IP66, 1-ph 230V, 16A |
63205 |
Yes |
Yes |
Yes |
OPT-2-L1025-20-BFI |
Input AC-choke IP20 1-ph 230V, 25A |
63125 |
Yes |
Yes |
Yes |
OPT-2-L1025-66-BFI |
Input AC-choke IP66, 1-ph 230V, 25A |
63206 |
Yes |
Yes |
Yes |
OPT-2-L1035-20-BFI |
Input AC-choke IP20, 1-ph 230V, 35A |
TBD |
Yes |
Yes |
Yes |
3x380-500 VAC |
|
|
|
|
|
OPT-2-L3006-20-BFI |
Input AC-choke IP20, 3-ph 500V, 6A |
63204 |
Yes |
No |
Yes |
OPT-2-L3006-66-BFI |
Input AC-choke IP66, 3-ph 500V, 6A |
63207 |
Yes |
No |
Yes |
OPT-2-L3010-20-BFI |
Input AC-choke, IP20 3-ph 500V, 10A |
63127 |
Yes |
No |
Yes |
OPT-2-L3010-66-BFI |
Input AC-choke IP66, 3-ph 500V, 10A |
63208 |
Yes |
No |
Yes |
OPT-2-L3018-66-BFI |
Input AC-choke, IP66, 3-ph 500V, 18A |
63128 |
Yes |
No |
Yes |
OPT-2-L3036-20-BFI |
Input AC-choke, IP20 3-ph 500V, 36A |
63129 |
Yes |
No |
Yes |
OPT-2-L3050-20-BFI |
Input AC-choke, IP20 3-ph 500V, 50A |
63130 |
Yes |
No |
Yes |
OPT-2-L3090-20-BFI |
Input AC-choke, IP20 3-ph 500V, 90A |
63131 |
Yes |
No |
Yes |
OPT-2-L3200-00-BFI |
Input AC-choke, IP00 3-ph 500V, 200A |
63132 |
No |
Yes |
Yes |
OPT-2-L3300-00-BFI |
Input AC-choke, IP00 3-ph 500V, 300 A |
63133 |
No |
Yes |
Yes |
OPT-2-L3500-00-BFI |
Input AC-choke, IP00 3-ph 500V, 500 A, 4% Inductance |
63226 |
No |
Yes |
Yes |
OPT-2-L31500-00-BFI |
Input AC-choke, IP00 3-ph 500V, 500 A, 1% Inductance |
63227 |
No |
Yes |
Yes |
Input chokes to reduce harmonic currents and protection against voltage spikes | |||||
Name |
Function |
Item number |
BFI-E3 |
BFI-H3 |
BFI-P2 |
1x200-240 VAC |
|
|
|
|
|
OPT-2-L1016-20-BFI |
Input AC-choke IP20 1-ph 230V, 16A |
63124 |
Yes |
Yes |
Yes |
OPT-2-L1016-66-BFI |
Input AC-choke IP66, 1-ph 230V, 16A |
63205 |
Yes |
Yes |
Yes |
OPT-2-L1025-20-BFI |
Input AC-choke IP20 1-ph 230V, 25A |
63125 |
Yes |
Yes |
Yes |
OPT-2-L1025-66-BFI |
Input AC-choke IP66, 1-ph 230V, 25A |
63206 |
Yes |
Yes |
Yes |
OPT-2-L1035-20-BFI |
Input AC-choke IP20, 1-ph 230V, 35A |
TBD |
Yes |
Yes |
Yes |
3x380-500 VAC |
|
|
|
|
|
OPT-2-L3006-20-BFI |
Input AC-choke IP20, 3-ph 500V, 6A |
63204 |
Yes |
No |
Yes |
OPT-2-L3006-66-BFI |
Input AC-choke IP66, 3-ph 500V, 6A |
63207 |
Yes |
No |
Yes |
OPT-2-L3010-20-BFI |
Input AC-choke, IP20 3-ph 500V, 10A |
63127 |
Yes |
No |
Yes |
OPT-2-L3010-66-BFI |
Input AC-choke IP66, 3-ph 500V, 10A |
63208 |
Yes |
No |
Yes |
OPT-2-L3018-66-BFI |
Input AC-choke, IP66, 3-ph 500V, 18A |
63128 |
Yes |
No |
Yes |
OPT-2-L3036-20-BFI |
Input AC-choke, IP20 3-ph 500V, 36A |
63129 |
Yes |
No |
Yes |
OPT-2-L3050-20-BFI |
Input AC-choke, IP20 3-ph 500V, 50A |
63130 |
Yes |
No |
Yes |
OPT-2-L3090-20-BFI |
Input AC-choke, IP20 3-ph 500V, 90A |
63131 |
Yes |
No |
Yes |
OPT-2-L3200-00-BFI |
Input AC-choke, IP00 3-ph 500V, 200A |
63132 |
No |
Yes |
Yes |
OPT-2-L3300-00-BFI |
Input AC-choke, IP00 3-ph 500V, 300 A |
63133 |
No |
Yes |
Yes |
OPT-2-L3500-00-BFI |
Input AC-choke, IP00 3-ph 500V, 500 A, 4% Inductance |
63226 |
No |
Yes |
Yes |
OPT-2-L31500-00-BFI |
Input AC-choke, IP00 3-ph 500V, 500 A, 1% Inductance |
63227 |
No |
Yes |
Yes |
Output chokes to reduce dV/dt and when long motor cables | |||||
Name |
Function |
Item number |
BFI-E3 |
BFI-H3 |
BFI-P2 |
OPT-2-M3008-20-BFI |
Output Choke, IP20, 3-ph 500V, 8 A |
63134 |
Yes |
Yes |
Yes |
OPT-2-M3008-66-BFI |
Output Choke, IP66, 3-ph 500V, 8 A |
63220 |
Yes |
Yes |
Yes |
OPT-2-M3012-20-BFI |
Output Choke, IP20, 3-ph 500V, 12 A |
63135 |
Yes |
No |
Yes |
OPT-2-M3012-66-BFI |
Output Choke, IP66, 3-ph 500V, 12 A |
63221 |
Yes |
No |
Yes |
OPT-2-M3018-66-BFI |
Output Choke, IP66, 3-ph 500V, 18 A |
63222 |
Yes |
No |
Yes |
OPT-2-M3030-20-BFI |
Output Choke, IP20, 3-ph 500V, 30 A |
63136 |
Yes |
No |
Yes |
OPT-2-M3075-20-BFI |
Output Choke, IP20, 3-ph 500V, 75 A |
63223 |
Yes |
No |
Yes |
OPT-2-M3180-00-BFI |
Output Choke, IP00, 3-ph 500V, 180 A |
63224 |
No |
No |
No |
OPT-2-M3300-00-BFI |
Output Choke, IP00, 3-ph 500V, 300 A |
63140 |
No |
No |
No |
OPT-2-M3500-00-BFI |
Output Choke, IP00, 3-ph 500V, 500 A |
63225 |
No |
No |
No |
External EMC-filters for improved EMC performance | |||||
Name |
Function |
Item number |
BFI-E3 |
BFI-H3 |
BFI-P2 |
1x200-240 VAC |
|
|
|
|
|
OPT-2-E1010-20-BFI |
External EMC Filter 1-ph 240V – 10A IP20 |
63114 |
Yes |
Yes |
Yes |
OPT-2-E1010-66-BFI |
External EMC Filter 1-ph 240V – 10A IP66 |
63210 |
Yes |
Yes |
Yes |
OPT-2-E1025-20-BFI |
External EMC Filter 1-ph 240V – 25A IP20 |
63115 |
Yes |
Yes |
Yes |
OPT-2-E1025-66-BFI |
External EMC Filter 1-ph 240V – 25A IP66 |
63211 |
Yes |
Yes |
Yes |
3x380-500 VAC |
|
|
|
|
|
OPT-2-E3006-20-BFI |
External EMC Filter 1-ph 240V – 10A IP20 |
63116 |
Yes |
Yes |
Yes |
OPT-2-E3006-66-BFI |
External EMC Filter 1-ph 240V – 10A IP66 |
63212 |
Yes |
Yes |
Yes |
OPT-2-E3016-20-BFI |
External EMC Filter 3-ph 480V – 16A IP20 |
63117 |
Yes |
Yes |
Yes |
OPT-2-E3016-66-BFI |
External EMC Filter 3-ph 480V – 16A IP66 |
63213 |
Yes |
Yes |
Yes |
OPT-2-E3025-20-BFI |
External EMC Filter 3-ph 480V – 25A IP20 |
63118 |
Yes |
Yes |
Yes |
OPT-2-E3025-66-BFI |
External EMC Filter 3-ph 480V – 25A IP66 |
63214 |
Yes |
Yes |
Yes |
OPT-2-E3050-20-BFI |
External EMC Filter 3-ph 480V – 50A IP20 |
63155 |
Yes |
Yes |
Yes |
OPT-2-E3080-20-BFI |
External EMC Filter 3-ph 480V – 80A IP20 |
63216 |
Yes |
Yes |
Yes |
OPT-2-E3180-20-BFI |
External EMC Filter 3-ph 480V – 180A IP20 |
63156 |
No |
Yes |
Yes |
OPT-2-E3300-00-BFI |
External EMC Filter 3-ph 480V – 300A IP00 |
63157 |
No |
Yes |
Yes |
OPT-2-E3500-00-BFI |
External EMC Filter 3-ph 480V – 500A IP00 |
65217 |
No |
Yes |
Yes |
Cooling fans
BFI warranty extended to 3 years
Beijer Electronics has the pleasure to announce that the Warranty for all types of Beijer Frequency Inverters, BFI, being produced from 1 of June 2024 is extended from 2 to 3 years. “We are very proud and comfortable with our quality and want to share this with our customers” says Product Manager Jan Strandberg. It's also possible to extend the warranty further to another 5 years for a small fee.